Sensors for portable hardness tester Equotip3

Print

The portable hardness tester Equotip 3 may be combined with many different impact devices and support rings, allowing a wide range of different materials, surfaces and part geometries to be measured. These significantly extend the possibility of applications for the Equotip device. Each of these special impact devices is compatible with basic unit Equotip 3 and is supplied as accessory.

Equotip Impact Devices

Type Application Impact energy Weight Photo
D Universal unit.
For the majority of your hardness testing requirements.
11 Nmm 75 g
G Increased impact energy.
For solid components, e.g. heavy castings and forgings.
90 Nmm 250 g
DL Slim front section.
For measurements in confined spaces, at the base of grooves or on recessed surfaces.
Note: The impact device DL can only be used with manual correction for impact direction.
11 Nmm 100 g
S Ceramics ball indenter.
For measurements in the very high hardness range (always in excess of 50 HRC / 650 HV): Tool steels with high carbide content inclusions.
11 Nmm 80 g
C Reduced impact energy.
Surface hardened components, coatings, thin walled or impact sensitive components (small measuring indentation).
3 Nmm 75 g
DC Short device.
For use in very confined spaces, e.g. in holes, cylinders or for internal measurements on assembled machines.
11 Nmm 50 g
E Diamond ball indenter.
For measurements especially in the very high hardness range (in excess of 50 HRC / 650 HV): Tool steels with high carbide content inclusions.
11 Nmm 80 g  
 